Banca de DEFESA: JOAO MARCOS TEIXEIRA LACERDA

Uma banca de DEFESA de DOUTORADO foi cadastrada pelo programa.
DISCENTE : JOAO MARCOS TEIXEIRA LACERDA
DATA : 16/06/2017
HORA: 08:00
LOCAL: Laboratorio de Inovação de Tecnológica em Saúde
TÍTULO:
SOA-BD: Service Oriented Architecture for Biomedical Devices

PALAVRAS-CHAVES:
SOA-BD, Telehealth, Biomedical devices interoperability, Service Oriented Architecture, HL7, Intensive care unit.

PÁGINAS: 40
GRANDE ÁREA: Engenharias
ÁREA: Engenharia Biomédica
RESUMO:

 The communication of information systems with biomedical devices has become complex not only due to the existence of several private communication protocols, but also to the immutable way that software is embedded into these devices. In this sense, this paper proposes a service-oriented architecture to access biomedical devices as a way to abstract the mechanisms of writing and reading data from these devices, thus contributing to enable the focus of the development team of biomedical software to be intended for its functional requirements, i.e. business rules relevant to the problem domain. The SOA-BD architecture consists of six main components: A Web Service for transport and conversion of the device data, Communication Protocols to access the devices, Data Parsers to preprocess data, a Device Repository to store data and transmitted information, Error handling, for error handling of these information and Setup, for configuration of the architecture. For the development of SOA-BD, technologies such as the XML language and the Java programming language were used. Besides, Software Engineering concepts such as Design Patterns were also used. For the validation of this work, data has been collected from vital sign monitors in an Intensive Care Unit using the HL7v2.x standard. The tests obtained a difference of about only 1 second in terms of response time with the use of SOA-BD. For conclusive purposes, SOA-BD achieves important results such as the reduction on the access protocol complexity, the opportunity for treating patients over long distances, allowing easier development of monitoring applications and interoperability with biomedical devices from diverse manufacturers.


MEMBROS DA BANCA:
Presidente - 2488270 - RICARDO ALEXSANDRO DE MEDEIROS VALENTIM
Interno - 1837410 - VALENTIN OBAC RODA
Externo ao Programa - 2562782 - KARILANY DANTAS COUTINHO
Externo à Instituição - ANTONIO HIGOR FREIRE DE MORAIS - IFRN
Externo à Instituição - JOSÉ MACEDO FIRMINO FILHO - IFRN
Externo à Instituição - PEDRO FERNANDES RIBEIRO NETO - UERN
Notícia cadastrada em: 06/06/2017 11:09
SIGAA | Superintendência de Tecnologia da Informação - (84) 3342 2210 | Copyright © 2006-2024 - UFRN - sigaa06-producao.info.ufrn.br.sigaa06-producao